TOP 4 pm2.5/10 sensors
What is the pm2.5
PM2.5 refers to solid particles and liquid droplets in ambient air with an aerodynamic diameter of 2.5 microns or less. It has a small particle size and is rich in a large number of toxic and harmful substances. It is longer than the atmospheric particles in the atmosphere residence time, transport distance is longer, to human health and atmospheric environment is more harmful.For pm2.5/10 monitoring, we can use special particulate matter sensor pm2.5/10 sensor.
Principle and method of measuring PM2.5 concentration
PM2.5 particles are invisible to the human eye. To know its concentration in the air, we need to use sensors to achieve it. At present, the principles and methods for measuring the concentration of PM2.5 are as follows:
1, infrared and turbidity method: infrared due to lack of light intensity, can only be measured by the turbidity method. The so-called turbidimetry is one side of the light, the other side of the reception. The more cloudy the air, the more energy the light loses, which determines the current air opacity. This method cannot accurately measure PM2.5, even if the luminescent and receiving parts are covered by electrostatic adsorbed dust, which will directly lead to inaccurate measurements. Sensors made in this way can only be measured qualitatively because the values will drift and cannot be measured quantitatively. More importantly, this method cannot distinguish the particle size, so the sensor will not perform well.
2.Grameric method: through a sampler with certain cutting characteristics, a quantitative volume of air is extracted at a constant speed, so that PM2.5 and PM10 in the ambient air are trapped on the filter membrane with known mass. The concentration of PM2.5 and PM10 is calculated according to the difference of mass and sampling quantity of the membrane before and after filter sampling. It should be noted that the volume of the denominator in the unit of particle measurement, ug/m3, should be the volume under standard conditions (0℃, 101.3kPa), and the volume under the measured temperature and pressure is converted into a volume under standard conditions.
3, laser scattering measurement method: laser scattering technology refers to the laser as the light source, in addition to the direction of the incident light, by detecting the intensity of the scattered light, frequency shift and Angle dependence, to get the weight, size, distribution and polymerization structure of the particle. The general term information methods has a wide range of uses.
More Gas Sensors:
Air Quality Monitoring System-SO2,NO2,CO,O3 ,pm2.5,pm10
Air quality monitoring station, grid air environment monitoring system, micro air monitoring station are used to provide products for real-time and accurate monitoring of outdoor air pollutants. The air quality monitoring station adopts an integrated sensor, which is light and small, beautiful in appearance, and easy to install. It can be calibrated according to the site, and customers can choose corresponding products according to specific needs or environments. The air quality monitoring system is used to provide products for real-time and accurate monitoring of outdoor air pollutants. The air quality monitoring system integrates.
PM2.5/10 monitoring-dust sensor
Particulate matter sensor (dust sensors) can be used for air monitoring in industrial plants/traffic tunnels/automobile exhaust/smog monitoring and other industrial and agricultural environments (pollution emission monitoring, atmospheric environment).The laser particulate matter sensor is a sensor that uses the scattering principle to detect dust particles in the air. It has small size, high detection accuracy, good repeatability, good consistency, real-time response and continuous collection, strong anti-interference ability, and must be tested and calibrated at the factory.
Air quality sensor indoor
(1)Standard guide rail structure design, exquisite appearance, screws installed on both sides, can be wall-mounted or ceiling-mounted. Two types of TVOC and TVOC+eCO can be detected.
(2)Built-in high-quality probes, using high-density material shell, wear-resistant and anti-drop, built-in high-quality probes, high accuracy, low power consumption, and wide range.
style 2:
(1)Surrounding heat dissipation design, good ventilation, fast heat dissipation and high sensitivity. It can detect TVOC+eCO, +PM2.5/10+temperature and humidity six in one.
(2) Single-hole fixing, easy to install, can be wall-mounted on the vertical ground.
(3) Built-in laser probe, high sensitivity.
style 3:
(1) Wall-mounted installation, installation of screws on both sides saves time and effort, and can also be installed on the ceiling.
(2) The built-in waterproof probe selects the photochemical gas detection probe for waterproof treatment, and the probe shell is designed with multiple pores to ensure air circulation and accurate data.
(3) Closed waterproof strip The built-in closed waterproof strip has a significant moisture-proof effect.
Particulate matter sensor module – dust sensor – pm2.5/10
Dust sensor module is used in air purifier, air quality detector, fresh air ventilation system, air conditioning with air purification function, automobile and supporting agricultural greenhouse of consumer electronics, outdoor breeding place, environmental monitoring, kitchen and bathroom ventilation control system, smart home equipment and other scenes.