TOP 5 CH4 Gas sensor
Background:
Biogas has proven to be a very good alternative to natural energy for electricity generation and is particularly popular because it is not affected by the weather. Using biogas, basic energy needs can be provided without grid fluctuations. However, according to the German Federal Environment Agency, biogas plants have a serious accident every two weeks. Of all recorded accidents, 46 percent involved fire, making it the most common type of accident. In the other 9 percent, there was at least one explosion. The reason will be the safety standard deviation of the plant. Methane (CH 4) can react explosively with air. This poses a potentially high risk to operators of biogas plants. When the concentration of methane in the air is between 4.4 % vol and 16.5 % vol, an explosive mixture is present. Therefore, it is important to pay attention to methane changes, which can be monitored online using the CH4 gas sensor.
For example, gas monitoring in a pump house can protect people from dangerous leaks. Continuous measurements in the biogas dome storage in the double film also ensure that there are no leaks and therefore no losses. In addition, escaped methane emissions have a negative impact not only on the profitability of biogas plants, but also on the climate, since methane is about 25 times more harmful to the climate than carbon dioxide. Therefore, personnel protection and plant safety are of Paramount importance when operating a biogas plant. With MSR-Electronic’s gas warning product, you can prevent hazards. Gas sensors, controllers and warning devices are used to measure combustible and toxic gases as well as oxygen. Leaks are thus located at an early stage.
Fixed Gas Detection-CH4 Gas Detector
Determination parameters: methane
Model: JXBS – 4001 – CH4 – RS
Communication mode: RS485, 0-5V, 0-10V, 4-20mA, 4g, NB-IOT, Ethernet
Power supply: 12-24V power supply
Measurement range: 0-100%lel
Measurement principle: catalytic combustion
Baud rate: 2400/4800/9600
Measurement accuracy: 3%F.s
Response time: (T90, seconds) : less than 15
Power consumption: ≤1W (@12V DC,25℃
Fixed gas detector, stable performance, sensitive and reliable. With high-precision liquid crystal display, explosion-proof housing, diffusion type or pump suction type. The CH4 Gas Detector has the characteristics of flexible use and simple operation. The CH4 Gas Detector is used in various gas leakage places, such as: city gas, petroleum, chemical, pharmaceutical, steel, special industrial plants and other fields. The explosion-proof level of the CH4 Gas Detector is CT6.
Portable CH4 Gas sensor
Response time: T90<30 seconds
Operating temperature: -20°C to 50° C
Operating humidity: 95%RH without condensation
Power supply: 3.6VDC,1500mAh(standard) lithium battery
Display mode: 2.2 inch LCD screen
The CH4 gas detector can detect Methane. CH4 gas detector can realize free combination of multiple parameters, support customization, 4G transmission mode can be selected, data can be viewed remotely, and the operation is simple.CH4 gas detector, waterproof, dustproof, accurate detection data, sound and light alarm, long service life. The CH4 gas detector can be used in gas leakage, pharmaceutical factories and other scenes.
NDIR Modules Detect CH4 Gas tester
Determination parameters: methane
CH4 Measurement range: 0-100000ppm
Communication port: 0-5v
Power supply: 9V-24V DC
Measurement principle: NDIR
Measurement accuracy: ±5%F.S(25℃)
Response time: < 30s (25℃)
Average power consumption: <60mA
CH4 gas sensor module adopts non dispersive infrared technology, which has the characteristics of high sensitivity, high resolution, oxygen free dependence, stable signal, accurate measurement, low power consumption and long service life. CH4 gas sensor module has diffusion type and pump type, which can be selected according to the demand.
Combustible gas sensor module-CH4
CH4 Measurement range: 0-100%
Communication port: TTL+ analog voltage
Power supply: 5V±2%
Measurement principle: catalytic combustion type
Measurement accuracy: ≤ ±3% of reading (25℃)
Response time: generally less than 15 seconds
Power consumption: 0.2 W or less
Combustible gas sensor module, strong anti-interference ability, high sensitivity, high resolution, small size, easy to install, no secondary calibration, support secondary development.CH4 gas sensor module is widely used in HVAC fresh air control / indoor air quality monitoring / agricultural and animal husbandry production process monitoring. It can be installed in intelligent buildings / ventilation system controller / wall mounted use / robot / automobile and other applications.
CH4 gas alarm control system
The CH4 gas detector has four configurations to choose from: standard configuration (real-time monitoring of the measured gas, high sensitivity, accurate measurement); with sound and light alarm (gas exceeding standard, sound and light alarm); with concentration display (real-time display of the detected gas value ); with concentration display and audible and visual alarm (display the gas concentration at the time, the data exceeds the standard alarm).